Two Vitamin D Immunoassays Compared

By LabMedica International staff writers
Posted on 20 Aug 2019
Print article
Image: The Architect 25-OH Vitamin D reagent kit (Photo courtesy of Abbott).
Image: The Architect 25-OH Vitamin D reagent kit (Photo courtesy of Abbott).
Vitamin D can be synthesized in skin from 7-dehydrocholesterol following ultraviolet light exposure, which produces Vitamin D3 (cholecalciferol). Vitamin D2 (ergocalciferol) is present in plant sources, and can be absorbed from the diet.

Measurement of 25-Hydroxyvitamin D (25-OH-D) is commonly performed to assess Vitamin D status in clinical laboratories; however, the ability of these assays to detect Vitamin D2 (as 25-OH-D2) or Vitamin D3 (as 25-OH-D3) varies. Assessment of Vitamin D status by measurement of 25-Hydroxyvitamin D (25-OH-D) is widely performed by immunoassay.

Biochemists at Baylor College of Medicine (Houston, TX, USA) and their colleagues evaluated the performance of the institution's total 25-OH-D assay on the Architect i1000 SR platform to detect either 25-OH-D2 or 25-OH-D3. This assay is a chemiluminescent microparticle immunoassay. Samples spiked with either 25-OH-D2 or 25-OH-D3 and reference laboratory samples with either 25-OH-D2 or 25-OH-D3 concentrations determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used for evaluation. As a comparison to the Architect assay, samples were also tested on the Cobas 8000, which uses an electrochemiluminescence binding assay.

The scientists reported that recovery of 25-OH-D3 in spiked samples was similar by Architect (84%–87%) and Cobas (90%). Recovery of 25-OH-D2 was lower than 25-OH-D3, and was poorer by Architect (37%–40%) than by Cobas (69%–71%). In measurement of samples with known 25-OH-D concentrations, performance of Architect and Cobas assays was similar for 25-OH-D3. However, at concentrations greater than 50 nmol/L 25-OH-D2, the Architect assay exhibited large average negative bias of −27%.

The authors concluded that while the Architect and Cobas assays performed similarly in detection of 25-OH-D3, the Architect assay was significantly poorer at detecting 25-OH-D2 than Cobas, with poorer recovery and significant negative bias at higher concentrations of 25-OH-D2. This agrees with other studies, and indicates that caution should be used in interpreting Architect 25-OH-D results in patients supplemented with Vitamin D2. The study was published on July 29, 2019, in the journal Practical Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.