By LabMedica International staff writers
Posted on 27 Jun 2019
Print article
Image: Blue-stained dots are Chikungunya virus particles peppering the surface of an infected cell (Photo courtesy of Institute Pasteur/Thérèse Couderc).
Image: Blue-stained dots are Chikungunya virus particles peppering the surface of an infected cell (Photo courtesy of Institute Pasteur/Thérèse Couderc).
Chikungunya virus has re-emerged as an important pathogen causing several outbreaks in the world. As the clinical symptoms of chikungunya are similar to other mosquito-borne febrile diseases, the definitive diagnosis of the disease is based on the detection of viral genome from the patient blood.

Loop-mediated isothermal amplification (LAMP) is a method that rapidly amplifies nucleic acids under isothermal condition. The method can be applied to detect genomes of RNA viruses if reverse transcriptase is included in the reaction (reverse transcription LAMP; RT-LAMP). Using the LAMP and RT-LAMP methods, amplification reaction of nucleic acids can be performed under isothermal conditions without expensive or sophisticated equipment.

An international team of scientists working with Hokkaido University (Sapporo, Japan) detected and sequenced the chikungunya virus (CHIKV) genome by performing a combination of a modified reverse transcription loop-mediated isothermal amplification (RT-LAMP) method and a MinION sequencer. They developed the protocol for drying all the reagents for the RT-LAMP in a single reaction tube.

The team found that using this system, the CHIKV genome was effectively amplified under isothermal conditions, and used as a template for MinION sequencing with a laptop computer. The assay was also validated using clinical samples. Serum samples were obtained from clinically suspected patients collected in 2016 and 2018, and which had been stored at the Oswaldo Cruz Institute. The obtained sequence data confirmed the CHIKV outbreaks and identified the genotype.

The authors concluded that a one-step, easy gene amplification assay for CHIKV genome detection was successfully developed. The assay was evaluated with RNA and serum samples from 16 CHIKV serology positive patients during recent chikungunya outbreaks in Rio de Janeiro, Brazil. In combination with MinION sequencing technology, they also identified the CHIKV genotypes with a laptop computer. The developed CHIK-CZC-LAMP diagnostics and MinION sequencing workflow will certainly contribute to future outbreak analysis in resource-limited settings. The study was published on June 3, 2019, in the journal PLOS Neglected Tropical Diseases.

Related Links:
Hokkaido University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.