We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Saliva-based Test Detects Infectious Subclinical Malaria

By LabMedica International staff writers
Posted on 27 Feb 2019
Print article
Image: A male and a female gametocyte of Plasmodium falciparum (Photo courtesy of Professor David Baker).
Image: A male and a female gametocyte of Plasmodium falciparum (Photo courtesy of Professor David Baker).
Low-density subclinical infection with Plasmodium falciparum among defined population subsets has been shown to be an important but cryptic facet of malaria transmission. Typically, these individuals are not readily detected by currently available point-of-need (PON) rapid diagnostic tests (RDTs) or microscopy.

The use of blood for screening campaigns substantially increases the inherent risk to both the screener and the individual (patient), and complicates the logistics, training requirements, and efficiency of the surveillance effort. Recently, it has been shown that parasite or pathogen biomarkers can enter into other biofluids, specifically urine and saliva.

An international team of scientists working with the Johns Hopkins Malaria Research Institute (Baltimore, MD, USA) developed a prototype antibody-based lateral flow immunoassay (LFIA) rapid test that validated the presence of the marker in saliva from children with subclinical infection, revealing an underappreciated amount of subclinical carriage in two malaria-endemic countries. The team performed a cross-sectional, multi-omics study of saliva from 364 children with subclinical infection in Cameroon and Zambia and produced a prototype saliva-based point-of-need (PON) lateral flow immunoassay test for P. falciparum gametocyte carriers.

The investigators performed a competitive profiling study using a liquid chromatography–multiple reaction monitoring (LC-MRM) mass spectrometry (MS) approach to estimate the prevalence of the candidate marker in the saliva of children with subclinical infection in Cameroon and Zambia and compared to microscopy and polymerase chain reaction (PCR) analyses of matched blood samples. The scientists detected in the pooled saliva from the children 35 proteins and PF3D7_1218800 was the most abundant in individual saliva samples from children who were found to be gametocyte positive by blood film microscopy.

The authors concludes that the identification of other parasite-derived antigens in the saliva such as PF3D7_0507800 and PF3D7_0906100, both of which are shared between gametocytes and asexual stages, can lead the way to an optimized, highly sensitive saliva-based RDT for both clinical studies and clinical settings. The test is capable of identifying submicroscopic carriage in both clinical and nonclinical settings and is compatible with archived saliva samples. The study was published on January 2, 2019, in the journal Science Translational Medicine.

Related Links:
Johns Hopkins Malaria Research Institute

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.