Novel POC Troponin Assay Rules Out Acute MI

By LabMedica International staff writers
Posted on 05 Nov 2018
Print article
Image: The i-STAT cardiac troponin I assay; healthcare professionals can obtain quantitative measurement of cardiac troponin I (cTnI) in ten minutes without leaving the patient\'s side (Photo courtesy of Abbott Point of Care).
Image: The i-STAT cardiac troponin I assay; healthcare professionals can obtain quantitative measurement of cardiac troponin I (cTnI) in ten minutes without leaving the patient\'s side (Photo courtesy of Abbott Point of Care).
More than seven billion diagnostic tests are run in the USA each year to help physicians make accurate, timely decisions about a person's medical treatment. Emergency department (ED) investigations of patients with suspected acute myocardial infarction (AMI) are time consuming, partly because of the turnaround time of laboratory tests.

Point-of-care diagnostic tests, that can often provide results within minutes, are used globally as hospitals face increased pressures to address overcrowding in emergency rooms and longer wait times. The goal of with-patient diagnostic tests is to deliver results with accuracy similar to the gold standard of high-sensitivity laboratory tests.

A team of scientists collaborating with Christchurch Hospital (Christchurch, New Zealand) evaluated 354 adults, including 255 (72.0%) men; mean age, 62 ± 12 years, who entered an emergency department with symptoms of acute coronary syndrome, such as a heart attack. Troponin concentrations were measured on ED arrival with both a novel point-of-care assay i-STAT TnI-Nx and a high-sensitivity troponin I assay, the Architect hs-cTnI.

The investigators reported that of 354 patients, 57 (16.1%) experienced an AMI. Eighty-five patients (24.0%) presented to the ED less than three hours after symptom onset. No difference was found between the area under the curve (AUC) of the TnI-Nx assay (0.975) and the hs-cTnI assay (0.970). A TnI-Nx assay result of less than 11 ng/L identified 201 patients (56.7%) as low risk, with sensitivity and a negative predictive value of 100%. In comparison, an hs-cTnI assay result of less than 3 ng/L identified 154 patients (43.5%) as low risk, with a sensitivity and a negative predictive value of 100%.

The authors concluded that a novel point-of-care troponin assay that can produce a result 15 minutes after blood sampling had comparable discrimination ability to an hs-cTnI assay for ruling out AMI after a single blood test. Use in the ED may facilitate earlier decision-making and could expedite the safe discharge of a large proportion of low-risk patients. Additional usefulness of this assay is likely to be found outside of the ED, such as in rural hospitals and general practices where there is limited rapid access to laboratory-based troponin assays. The study was published on October 17, 2018, in the journal JAMA Cardiology.

Related Links:
Christchurch Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.