We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Human Pegivirus Identified in Encephalitis Patients

By LabMedica International staff writers
Posted on 17 Oct 2018
Print article
Image: The MiSeq Sequencing platform (Photo courtesy of Illumina).
Image: The MiSeq Sequencing platform (Photo courtesy of Illumina).
Human pegivirus (HPgV), was previously called hepatitis G virus or GB virus C, and is a lymphotropic virus with undefined pathology and many viruses from the family Flaviviridae, to which HPgV belongs, are neurotropic.

Infection with HPgV is common worldwide; about 5% of healthy blood donors in industrialized countries are viremic, whereas in some developing countries the prevalence of viremia among blood donors is approximately 20%. There is evidence that HPgV is transmitted parenterally, sexually, and also vertically from mother to child. However, the high proportion of HPgV infection in apparently healthy blood donors and the general population suggests existence of nonparenteral routes.

Scientists from the Medical University of Warsaw (Warsaw, Poland) and their colleagues prospectively enrolled 96 patients with encephalitis at the Warsaw Hospital for Infectious Diseases (Warsaw, Poland) from June 2012 through July 2015. They collected cerebrospinal fluid (CSF) and serum samples from patients at admission (5 to 7 days after symptom onset).

They tested the samples from all 96 patients for the presence of 5′ untranslated region (UTR) HPgV RNA. The team performed real-time quantitative PCR (qPCR) or real-time quantitative reverse transcription PCR (qRT-PCR) to detect other viruses. They detected autoantibodies against neuronal surface antigens using the Autoimmune Encephalitis Mosaic 6 assay. They subjected the amplified PCR products to single-strand conformational polymorphism analysis. The reamplified RT-PCR products with primers specifically designed for the Illumina MiSeq platform.

The scientists found HPgV in serum and cerebrospinal fluid from three patients who had encephalitis of unclear origin; that is, all the markers that had been tested were negative. Single-strand confirmation polymorphism and next-generation sequencing analysis revealed differences between the serum and cerebrospinal fluid–derived viral sequences, which is compatible with the presence of a separate HPgV compartment in the central nervous system.

The authors concluded that they had detected HPgV sequences in the CSF of three patients with encephalitis of unclear origin, and these sequences from CSF differed from those circulating in serum. These findings are compatible with the presence of a separate viral compartment in the CNS. Determining if the pegivirus was responsible for encephalitis or if it was present along with another cause of encephalitis will require further studies including histopathological analysis. The study was published in the October 2018 issue of the journal Emerging Infectious Diseases.

Related Links:
Medical University of Warsaw
Warsaw Hospital for Infectious Diseases

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.