We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Continuous Glucose Monitoring System Offers Improved Accuracy

By LabMedica International staff writers
Posted on 23 Aug 2018
Print article
Image: The Dexcom G6 continuous glucose monitoring family with applicator (Photo courtesy of Dexcom).
Image: The Dexcom G6 continuous glucose monitoring family with applicator (Photo courtesy of Dexcom).
Frequent use of continuous glucose monitoring systems is associated with improved glycemic outcomes in persons with diabetes, but the need for calibrations and sensor insertions are often barriers to adoption.

A newly improved, factory-calibrated, continuous glucose monitoring (CGM) system provided accurate glucose readings for 10 days (240 hours) and removed a number of clinical barriers to widespread CGM use, such as acetaminophen interference and complicated adjustments.

Scientists at the University of Colorado Denver (Aurora, CO, USA) and their colleague tested the accuracy of the improved G6 CGM system, which includes a thinner and smaller transmitter, predictive low glucose alert, sensor membrane to block acetaminophen, and 10-day sensor wear. The current study enrolled 151 youth (age 6 to 17) and 139 adults with type 1 and 2 diabetes from 11 sites within the USA.

Youth participants returned for one clinic session of six hours, and adults for three clinic sessions of up to three hours, during which CGM readings were compared with venous glucose concentrations in a laboratory setting. Glucose levels were manipulated for the 202 participants over the age of 13 to determine that the G6 CGM system, was adequately covering the entire reportable 40-400 mg/dL range. Performance evaluation included the proportion of CGM values that were within ±20% of reference glucose values greater than 100 mg/dL or within ±20 mg/dL of reference glucose values ≤100 mg/dL (%20/20), the analogous (%15/15), and the mean absolute relative difference (MARD, expressed as a percentage) between temporally matched CGM and reference values.

The data from 262 study participants (21,569 matched CGM reference pairs) were analyzed. The overall %15/15, %20/20, and MARD were 82.4%, 92.3%, and 10.0%, respectively. Matched pairs from 134 adults and 128 youth of ages 6–17 years were similar with respect to %20/20 (92.4% and 91.9%) and MARD (9.9% and 10.1%). Overall %20/20 values on days 1 and 10 of sensor wear were 88.6% and 90.6%, respectively. The system's “Urgent Low Soon” (predictive of hypoglycemia within 20 minutes) hypoglycemia alert was correctly provided 84% of the time within 30 minutes before impending biochemical hypoglycemia (<70 mg/dL). The 10-day sensor survival rate was 87%.

The authors concluded that the new factory-calibrated G6 real-time CGM system provides accurate readings for 10 days and removes several clinical barriers to broader CGM adoption. The study was published online on June 1, 2018, in the journal Diabetes Technology & Therapeutics.

Related Links:
University of Colorado Denver

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Molecular Diagnostics

view channel
Image: AI analysis of DNA fragmentomes and protein biomarkers noninvasively detects ovarian cancer (Photo courtesy of Adobe Stock)

Blood-Based Machine Learning Assay Noninvasively Detects Ovarian Cancer

Ovarian cancer is one of the most common causes of cancer deaths among women and has a five-year survival rate of around 50%. The disease is particularly lethal because it often doesn't cause symptoms... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Pathology

view channel
Image: The device can serve as a sample pretreatment tool for cytological diagnosis of malignant effusions (Photo courtesy of Microsystems & Nanoengineering: Zhu, Z., Ren, H., Wu, D. et al.)

Microfluidic Device for Cancer Detection Precisely Separates Tumor Entities

Tumor cell clusters are increasingly recognized as crucial in cancer pathophysiology, with growing evidence of their increased resistance to treatment and higher metastatic potential compared to single tumor cells.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.