Urine Test Accurately Detects Bladder Cancer Recurrence

By LabMedica International staff writers
Posted on 10 Aug 2018
Print article
Image: The Bladder EpiCheck diagnostic kit (Photo courtesy of Nucleix).
Image: The Bladder EpiCheck diagnostic kit (Photo courtesy of Nucleix).
Urinary tests have been studied for the detection of bladder tumors; however, most of these tests have not been implemented in clinical practice because of cost issues, practical aspects, or insufficient sensitivity or specificity as compared to the gold standard.

Bladder cancer, which ranks fifth among the most frequently diagnosed cancers in the EU, has a high disease recurrence rate, some 70%, requiring frequent follow-ups. The standard follow-up procedure includes a cystoscopy, and this procedure is coupled with a urine analysis to inspect for cancerous cells and, if needed, a biopsy of the suspect area.

Scientists at the Radboud University Nijmegen Medical Center (Nijmegen, The Netherlands) and their European colleagues performed a single-arm, prospective, double-blind clinical study was in five leading urology centers in Europe on 440 patients who were recruited in their first year of follow-up. Results for cystoscopy and cytology were noted, and if a lesion was detected, the date and result of histological confirmation were recorded.

The team collected a urine sample for the Bladder EpiCheck test (Nucleix, Rehovot, Israel) – a urine test developed to monitor recurrence of bladder cancer according to 15 DNA methylation biomarkers. The test was performed on ≥10 ml of urine and processed within five days in a central laboratory. Processing includes centrifugation to separate the cell pellet, from which DNA is extracted. The extracted DNA is digested using a methylation-sensitive restriction enzyme that cleaves DNA at recognition sequences if it is unmethylated, while leaving methylated sequences intact. Digested DNA is then amplified via real-time polymerase chain reaction with locus-specific primers and probes (eight wells per sample), and the resulting data are analyzed using the Bladder EpiCheck software.

Out of 440 patients recruited, 353 were eligible for the performance analysis. Overall sensitivity, specificity, negative predictive value (NPV), and positive predictive value were 68.2%, 88.0%, 95.1%, and 44.8%, respectively. Excluding low-grade (LG) Ta recurrences, the sensitivity was 91.7% and NPV was 99.3%. The area under receiver operating characteristic (ROC) curves with and without LG Ta lesions was 0.82 and 0.94, respectively. For the 403 patients with a Bladder EpiCheck result, 320 samples (81.1%) were negative and 83 (18.9%) were positive; the mean EpiScore was 31.2 ± 26.6.

Opher Shapira, PhD, the CEO of Nucleix Ltd, said, “With bladder cancer the problem is not early detection since it usually has signs like blood in the urine. The main problem is monitoring for recurrence of the cancer, because it is a highly recurrent disease. The standard procedures for monitoring causes repeated discomfort in patients and are very costly to the health system. The results of the test mean that physicians who prescribe our urine test for patients and get a no-cancer result back from the laboratory can be assured their patients do not have high grade tumors.” The study was published on July 15, 2018, in the journal European Urology Oncology.

Related Links:
Radboud University Nijmegen Medical Center
Nucleix
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.