We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Antibodies Interpreted after Scrub Typhus Infection

By LabMedica International staff writers
Posted on 25 Jun 2018
Print article
Image: Orientia tsutsugamushi (arrows) in culture of bronchoalveolar lavage fluid from a patient with acute respiratory distress syndrome (Photo courtesy of Aix Marseille Université).
Image: Orientia tsutsugamushi (arrows) in culture of bronchoalveolar lavage fluid from a patient with acute respiratory distress syndrome (Photo courtesy of Aix Marseille Université).
Scrub typhus is a zoonotic infection caused by the bacterium Orientia tsutsugamushi. It is transmitted to humans by the bite of the larval stage of trombiculid mites. With an annual incidence of about one million cases, it is an important challenge to public health in Southeast Asia.

The clinical presentation may vary from a mild febrile illness to a life-threatening disseminated infection with serious complications such as acute respiratory distress syndrome, hepatitis, renal failure, meningitis, and multiple organ failure, making the diagnosis difficult. The serological detection of IgM antibodies is the most widely used test to diagnose scrub typhus infection.

Scientists at the Christian Medical College (Vellore, India) included in this cross-sectional study, 203 patients over 18 years of age with previously confirmed scrub typhus. Scrub typhus was confirmed by positive immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) (optical density (OD) >0.8) and/or a positive polymerase chain reaction (PCR) for O. tsutsugamushi at a tertiary care teaching hospital in South India between December 2011 and March 2015.

The team performed ELISAs for IgM and IgG antibodies using the Scrub Typhus Detect kit (InBios International, Inc, Seattle, WA, USA). All patients had a positive IgM ELISA at diagnosis, of which 80 were confirmed by PCR. All patients had a blood sampling done during the study. Among them, eight patients had two blood samples taken at different time points. The time interval between confirmation of the original infection and study sample collection ranged from one month to 46 months. The overall trend showed a gradual fall in mean IgM levels over time, remaining above the threshold of positivity (OD >0.8) until 12 months after infection. The mean IgG levels showed a gradual rise, reaching a peak at 10 months post-infection, followed by a gradual decline, remaining above the cut-off threshold for more than 36 months.

The authors concluded that clinicians needed to be cautious in using a single serum sample for the detection of IgM to diagnose scrub typhus, as it remains elevated for up to 12 months after the infection, whereas the serum IgG level could be used as an indicator of past infection. The study was published in the June 2018 issue of the International Journal of Infectious Diseases.

Related Links:
Christian Medical College
InBios International
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.