Near-Patient Hepatitis C Assay Validated

By LabMedica International staff writers
Posted on 17 May 2018
Print article
Image: The Genedrive HCV ID kit is a qualitative assay providing results in 90 minutes in a decentralized environment (Photo courtesy of Genedrive).
Image: The Genedrive HCV ID kit is a qualitative assay providing results in 90 minutes in a decentralized environment (Photo courtesy of Genedrive).
Chronic infection with hepatitis C virus (HCV) is a major public health problem, estimated to infect 1.0% of the world’s population (71 million people) and to be responsible for 400, 000 annual deaths as a result of cirrhosis and liver cancer.

A hand-held, portable device that weighs approximately 600 grams or a little more than 21 ounces has been validated as a point-of-care molecular diagnostics system and assay for hepatitis C virus. A new study demonstrated proof of concept for a semi-quantitative assessment of HCV viral load using melting peak ratiometric analysis.

A team of international scientists collaborating with those at the Institute Pasteur (Paris, France) tested 130 clinical plasma and serum samples across three instruments and four operators. Samples were collected from various African countries, including Ghana, Kenya, Mauritius, Mozambique, Nigeria, South Africa, Uganda, and Zimbabwe, as part of routine HCV diagnostic testing using the Abbott RealTime HCV Genotype II on the Abbott m2000.

The team validated the Genedrive HCV point-of-care (POC) assay, which is a two-step procedure requiring a plasma or serum preparation step, followed by a reverse transcription (RT) reaction to generate the complementary DNA (cDNA) from the target HCV RNA. This cDNA undergoes asymmetric polymerase chain reaction (PCR) to generate linear amplification of single stranded products, followed by detection using a secondary hybridization probe and dissociation curve analysis.

The point-of-care assay identified all major HCV genotypes, with a limit of detection of 2,362 IU/mL (95% CI 1966 to 2788). Using 422 patients chronically infected with HCV and 503 controls negative for anti-HCV and HCV RNA, the Genedrive HCV assay showed 98.6% sensitivity (95% CI 96.9% to 99.5%) and 100% specificity (95% CI 99.3% to 100%) to detect HCV. In addition, melting peak ratiometric analysis demonstrated proof-of-principle for semi- quantification of HCV. The test was further validated in a real clinical setting in a resource-limited country.

The authors concluded that they had provided proof of concept in a real-life clinical setting that the Genedrive HCV assay has great potential to provide an affordable and robust instrument for decentralized HCV Nucleic Acid Amplification Testing (NAAT). This highly sensitive and specific test has recently obtained CE-IVD certification and is positioned to enable real-time treatment management of patients with chronic HCV in any clinical setting. The study was published on April 3, 2018, in the journal BMJ Gut.

Related Links:
Institute Pasteur

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.