We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Nanopore Method Developed for Genetic Screening

By LabMedica International staff writers
Posted on 12 Apr 2018
Print article
Image: The MinION is the only portable real-time device for DNA and RNA sequencing (Photo courtesy of Oxford Nanopore Technologies).
Image: The MinION is the only portable real-time device for DNA and RNA sequencing (Photo courtesy of Oxford Nanopore Technologies).
Rapid sequencing of short DNA reads may be useful for a wide range of clinical applications including targeted mutation analysis, cancer-panel testing, and aneuploidy screening. Fast, point-of-care preimplantation genetic screening could improve the success of in vitro fertilization procedures by not requiring embryos to be frozen.

However, the time and skill required for library preparation and sequencing using existing DNA sequencing methods limits their widespread clinical use. Nanopore sequencing technology is one of the fastest growing third generation next-generation sequencing (NGS) technologies. A new method that simplifies and accelerates nanopore-based short-length DNA library preparation and sequencing has been applied to test a panel of normal and aneuploid genomic DNA samples.

Scientists at the Columbia University Medical Center (New York, NY, USA) tested the new protocol on nine blinded samples. The nine samples included both diploid and aneuploid samples and one normal reference male sample. Trophoectoderm biopsy samples were taken from fresh, day-five embryos and sent to a reference laboratory for clinical preimplantation genetic screening (PGS) testing.

PGS screening was performed using the VeriSeq PGS assay with excess DNA used to run the MinION-based workflow. After sequencing, the scientists used only reads that were assigned to a barcode and uniquely matched to the reference genome for analysis. More than 70% of reads were assigned to a unique barcode, and of those, between 75% and 95%were uniquely assigned to the reference.

The investigators determined that to detect whole chromosome aneuploidy, 30,000 reads were needed. In the study, their results were concurrent with the VeriSeq PGS test. Of the nine samples, five were abnormal, including a female monosomy 22, female trisomy 19, female trisomy 22 and monosomy X, female trisomy 13 and monosomy 14, a male with an extra X chromosome and trisomy 15, and a female with trisomy 15 and monosomy 18 that was also mosaic for trisomy 6.

S. Zev Williams, MD, PhD, an Associate Professor of Obstetrics and Gynecology, and senior author of the study, said, “One limitation of nanopore sequencing has been its accuracy. However, since aneuploidy detection does not rely on calling point mutations, base-level accuracy is not as important. We want to have an accuracy of over 99%, and to test enough samples to be sure that's what it is will take time. Nonetheless, I think the potential is there.” The study was published in the April 2018 issue of the journal G3: Genes, Genomes, Genetics.

Related Links:
Columbia University Medical Center

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.