Ultra-Sensitive Rapid Test Evaluated for Malaria

By LabMedica International staff writers
Posted on 05 Apr 2018
Print article
Image: The Malaria Ag P.f test is 10 times more sensitive than current malaria rapid diagnostic tests for the detection of Plasmodium falciparum HRP-II antigen (Photo courtesy of Alere).
Image: The Malaria Ag P.f test is 10 times more sensitive than current malaria rapid diagnostic tests for the detection of Plasmodium falciparum HRP-II antigen (Photo courtesy of Alere).
In low prevalence regions, subpatent Plasmodium falciparum malaria infections have become an issue of increasing concern. As malaria endemic countries shift from control to elimination, the proportion of low-density P. falciparum infections increases.

Current field diagnostic tools, such as microscopy and rapid diagnostic tests (RDT), with detection limits of approximately 100 to 200 parasites/µL (p/µL) and 800 to1000 pg/mL histidine-rich protein 2 (HRP2), respectively, are unable to detect subpatent infections.

Scientists at Diagnostics Program, PATH (Seattle, WA, USA) tested two commercial available RDTs. The two RDTs are immunochromatographic membrane strip tests, but differ in that the ultra-sensitive (uRDT) one uses biotinylated and carboxyl-modified latex fragment antibodies (FAbs) and polystreptavidin bound to the test line to detect P. falciparum-specific HRP2 in whole blood. The uRDT test requires 5 µL of whole blood specimen and the blood is applied to the sample port in the test followed by application of four drops of assay diluent. Twenty minutes after application of the specimen, the result is interpreted from the result window.

The uRDT used was the Alere Malaria Ag P.f RDT and was compared to the BIOLINE Malaria Ag P.f RDT. The team reported that the uRDT detected dilutions of P. falciparum recombinant strains, as well as cultured strains, diluted in whole blood down to 10 to 40 pg/mL HRP2, depending on the protein tested. The uRDT specificity was 100% against 123 archived frozen whole blood samples. The commercial SD-RDT and uRDT detected pfhrp2 positive strains down to 49 and 3.13 p/µL, respectively. The pfhrp2 deletion strains were detected down to 98 p/µL by both tests.

The authors concludes that the performance of the uRDT was variable depending on the protein, but overall showed a greater than 10-fold improvement over the SD-RDT. The uRDT also exhibited excellent specificity and showed the same cross-reactivity with HRP3 as the SD-RDT. Together, the results support the uRDT as a more sensitive HRP2 test that could be a potentially effective tool in elimination campaigns. The study was published on March 17, 2018, in the Malaria Journal.

Related Links:
Diagnostics Program, PATH

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.