We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Rapid Salivary Test Developed for Zika Virus

By LabMedica International staff writers
Posted on 07 Mar 2018
Print article
Image: Detection in saliva of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis (Photo courtesy of New York University College of Dentistry).
Image: Detection in saliva of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis (Photo courtesy of New York University College of Dentistry).
Early pathogen identification is necessary to combat the spread of newly emerging and re-emerging epidemics. Diagnosis can be accomplished with a generic platform and protocol designed to identify any pathogen by detection of the pathogen’s nucleic acid once its sequence is determined and its antigenic footprint identified.

Blood samples are most often used to test for Zika virus (ZIKV) and are typically processed using a common diagnostic technique called real-time polymerase chain reaction (RT-PCR). However blood may not be the best fluid as the virus disappears in the blood a week or two after a person is infected, it can persist longer in saliva, semen, and urine.

Scientists at the New York University College of Dentistry (New York, NY, USA) and their colleagues developed a rapid Zika test that combines both nucleic acid and antibody assays using saliva, given that Zika virus and antibodies persist in saliva. A saliva test is also noninvasive, cost effective, and easier to collect than blood or urine. The team first optimized the reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay to detect ZIKV RNA using a benchtop isothermal amplification device and then adapted the assay to the CARD cartridge microfluidic device (Rheonix, Ithaca, NY, USA).

The microfluidic Rheonix CARD cartridge is an integrated cassette that can provide both an immunological and nucleic acid (RT-LAMP) result from a single sample. It incorporates all the pumps, valves, micro channels, reactions, and reagent reservoirs on a disposable cartridge. The processing and analysis on the Rheonix CARD cartridge is controlled by the Encompass Optimum workstation developed to provide automated control of all sample preparation functions.

The assay in a microfluidic device that will allow analyzing 24 samples simultaneously and automatically from sample introduction to detection by reverse dot-blot for detection (RDB) technique. Preliminary data using saliva samples spiked with ZIKV showed that the diagnostic system detects ZIKV RNA in saliva. The limit of detection of the RT-LAMP assay on the Genie III instrument (OptiGene, Horsham, UK) and Rheonix CARD cartridges is similar to other results reported using RT-LAMP and other isothermal assays. The study was published on February 5, 2018, in the journal Public Library of Science ONE.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.