We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

POLYMEDCO

Polymedco is a manufacturer and distributor for clinical laboratory supplies, including diagnostic test kits and devi... read more Featured Products: More products

Download Mobile App




Fecal Immunochemical Test Detects Cancer and Polyps

By LabMedica International staff writers
Posted on 30 Aug 2017
Print article
Image: The Polymedco OC auto 80 analyzer (Photo courtesy of Polymedco).
Image: The Polymedco OC auto 80 analyzer (Photo courtesy of Polymedco).
The most commonly used noninvasive test for colorectal cancer (CRC) screening has been the guaiac fecal occult blood test (gFOBT). The fecal immunochemical test (FIT) detects CRC and colorectal polyps with higher levels of sensitivity than the gFOBT, and may be more acceptable to patients.

The fecal immunochemical test (FIT), has shown to be more sensitive for CRC and colorectal polyps and may be more acceptable to patients because FIT can often be done with one sample, instead of three, and does not require dietary restrictions, such as meat avoidance. Screening can reduce incidence and mortality of CRC, but is often underused.

Scientists at the Veterans Administration San Diego Healthcare System (VASDH, San Diego, CA, USA) conducted a retrospective observational study of 7,898 patients, 50–75 years old, who were offered stool-based CRC screening as part of primary care March 2014 through January 2015. The team performed manual reviews of colonoscopy and pathology reports for veterans with positive results from the tests. The primary outcome was test completion within one year of order; secondary outcomes were positive results and detection of advanced neoplasia by diagnostic colonoscopy. The primary analysis used an intention-to-screen approach, which included all patients with test orders; as-screened analyses were also performed.

Before July 2014, when noninvasive CRC screening was offered, a three-sample Hemoccult Sensa gFOBT test was distributed at point of primary care and returned either by mail or in person. From July to August 2014, VASDHS transitioned to using a one-sample FIT (Polymedco OC auto 80, Cortland, NY, USA), also returned either by mail or in person. Colonoscopy and pathology reports were specifically reviewed to ascertain presence of any advanced neoplasia. Advanced neoplasia in this analysis included any CRC or advanced adenoma.

The investigators obtained 4,662 FIT orders and 3,236 gFOBT orders. In the intention to screen analysis, a significantly higher proportion of subjects completed a FIT (42.6%) than a gFOBT (33.4%). Advanced neoplasia was detected in a significantly higher proportion of subjects offered a FIT (0.79%) than a gFOBT (0.28%). The numbers needed to invite to achieve one additional completed test and identify one additional patient with advanced neoplasia were 11 and 196, respectively. The investigators estimate that for every 1,000 tests, FIT would yield 51 colonoscopies, compared with 42 for gFOBT.

Samir Gupta, MD, MSCS, AGAF, the study’s senior and corresponding author and a staff physician, said, “Many physicians are unaware of the difference between FIT and gFOBT, and potential advantages. One of our hopes is that the paper and other associated literature will help laboratory directors and primary care physicians to realize that making a simple switch could have big benefits for patients.” The study was published in the August 2017 issue of the journal Clinical Gastroenterology and Hepatology.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.