We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




New Test Rapidly Diagnoses Preeclampsia

By LabMedica International staff writers
Posted on 09 Aug 2017
Print article
Image: A histopathology of a glomerulus from a patient with preeclampsia revealing a pronounced bubbly appearance in the consolidated areas, caused by swollen endothelial cells and podocytes (Photo courtesy of Dr. Vivette D’Agati, MD).
Image: A histopathology of a glomerulus from a patient with preeclampsia revealing a pronounced bubbly appearance in the consolidated areas, caused by swollen endothelial cells and podocytes (Photo courtesy of Dr. Vivette D’Agati, MD).
Preeclampsia can lead to kidney damage in many affected women and the only therapy currently available is delivery of the baby, but this often means that infants are born prematurely and may have medical problems related to their early delivery.

More effective treatment strategies will depend on methods that would diagnose women with preeclampsia in a timely manner and a better understanding of preeclampsia’s underlying mechanisms. Recent studies indicate that preeclampsia is linked with the abnormal presence in the urine of podocytes; however, available tests that can identify podocytes are expensive and time-consuming.

An international team of scientists collaborating with those at the Mayo Clinic, (Rochester, MN, USA) recruited at delivery a study population included 49 preeclamptic and 42 normotensive pregnant women. Plasma measurements included cell free fetal hemoglobin (HbF) concentrations and concentrations of the endogenous chelators haptoglobin, hemopexin, and α1- microglobulin. They assessed concentrations of urinary extracellular vesicles (EVs) containing immunologically detectable podocyte-specific proteins by digital flow cytometry and measured nephrinuria by an enzyme-linked immunosorbent assay (ELISA).

When the team compared the urine from women with normotensive pregnancies with urine from women with preeclamptic pregnancies, the latter contained a high ratio of podocin-positive to nephrin-positive urinary EVs (podocin+ EVs-to-nephrin+ EVs ratio) and increased nephrinuria, both of which correlated with proteinuria. Plasma levels of hemopexin, which were decreased in women with preeclampsia, negatively correlated with proteinuria, urinary podocin+ EVs-to-nephrin+ EVs ratio, and nephrinuria. They also found that fetal haemoglobin, which is normally present in pregnant women’s blood in small amounts, is present in higher amounts in pre-eclamptic women’s blood.

The authors concluded that their findings provide evidence that urinary EVs are reflective of preeclampsia-related altered podocyte protein expression. Furthermore, renal injury in preeclampsia associated with an elevated urinary podocin+ EVs-to-nephrin+ EVs ratio and may be mediated by prolonged exposure to cell free HbF.

Vesna D. Garovic, MD, a professor of Nephrology and Hypertension and the senior author of the study, said, “This increased amount of fetal haemoglobin in preeclampsia may be causing the release of podocyte fragments in the urine. We hope that this information will result in improved diagnostic procedures in women with pre-eclampsia; however, additional studies in larger numbers of patients and across different types of preeclampsia are needed.” The study was published on July 20, 2017, in the journal Clinical Journal of the American Society of Nephrology.

Related Links:
Mayo Clinic

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.