We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Methods Compared for Chagas Disease Diagnosis

By LabMedica International staff writers
Posted on 08 Aug 2017
Print article
Image: The Professional Standard TRIO thermal cycler provides three independent 48 well blocks and heated lids in one housing (Photo courtesy of Biometra).
Image: The Professional Standard TRIO thermal cycler provides three independent 48 well blocks and heated lids in one housing (Photo courtesy of Biometra).
Chagas Disease (CD) is a chronic infectious disease caused by the protozoan flagellate Trypanosoma cruzi. In endemic countries, CD is transmitted mainly through the contact with feces of different triatomine bugs. Due to increased migration, CD has become an international health problem.

CD presents itself in two phases: whereas the acute phase is dominated by unspecific or no symptoms at all, in the chronic phase cardiac and/or gastrointestinal symptoms can occur after a long asymptomatic interval. Reliable diagnosis of chronically infected people is crucial for prevention of non-vectorial transmission as well as treatment.

European scientists led by those at the Medical Center of the University of Munich (Germany) tested samples consisting of 50 human EDTA blood samples that were previously tested positive by enzyme-linked immunosorbent assay (ELISA), immunofluorescence antibody test (IFAT) and polymerase chain reaction (PCR) for T. cruzi in the Instituto de Salud Carlos III, (Madrid, Spain) during 2010–2013. This study compared four distinct PCR methods for detection of T. cruzi DNA for the use in well-equipped routine diagnostic laboratories.

The team chose two conventional and two real-time PCR methods for closer evaluation. DNA was extracted of T. cruzi-positive and negative patients' blood samples and cultured T. cruzi, T. rangeli as well as Leishmania spp. One conventional and two real-time PCR methods targeting a repetitive satellite-DNA sequence as well as one conventional PCR method targeting the variable region of the kDNA minicircle were compared for sensitivity, intra- and interassay precision, limit of detection, specificity and cross-reactivity. For two methods the Professional Standard thermal cycler was operated, and for the other methods, the CFX C1000 Real-Time thermal cycler was used.

The team found that out of the 50 previously positive tested samples by serology and PCR, 44 samples were detected by all four methods. One method detected T. cruzi in all 50 samples. Potentially cross reactive agents (L. tropica, L. donovani, L. infantum, L. braziliensis, L. major, T. rangeli and T. brucei) showed similar results in all four methods. The costs of consumables are significantly cheaper for conventional methods than for real-time methods. The price of the conventional methods was below EUR 1/test, while it is around EUR two and eight per test for the relay time methods. The study was published in the July 2017 edition of the journal Diagnostic Microbiology and Infectious Disease.

Related Links:
Medical Center of the University of Munich
Instituto de Salud Carlos III

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.