Thromboelastometry Analysis Assessed for Thrombocytopenic Dengue Patients

By LabMedica International staff writers
Posted on 01 Feb 2017
Print article
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Dengue virus infection (DVI) is a prevalent and potentially fatal viral disease associated with coagulopathy. Dengue hemorrhagic fever (DHF) represents a severe clinical presentation of DVI and is characterized by the presence of varying degrees of hemostatic disorders.

Rotational thromboelastometry is a point of care test that promptly provides within 5 to 30 minutes information about the dynamics of clot formation, stabilization and dissolution, reflecting the in vivo hemostasis at the bedside.

Physicians at the Hospital Israelita Albert Einstein conducted a cross-sectional study during a DVI outbreak in São Paulo, Brazil, between April 6 and May 5, 2015. Patients with at least 24 hours of fever (axillary temperature greater than 37.8 °C), in addition to a positive dengue virus (DV) specific immunoglobulin IgM/IgG or non-structural protein-1 (NS1) antigen rapid test and platelet count less than 100 × 109/L were consecutively included in this study.

Rotational Thromboelastometry and the conventional coagulation tests prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), thrombin time (TT), platelet count and fibrinogen levels were performed in 53 patients with DVI and thrombocytopenia. Measurement of coagulation in ROTEM was performed after the vertical immersion of a plastic pin into the blood sample. The pin rotates slowly backwards and forwards through an angle of 4.75°. By generation of the first fibrin filaments between the pin and the wall of the test cup, the rotational range of the pin is reduced. The increased restriction of the pin’s movement is transferred to a graphical display, a plot that shows changes in the viscoelastic properties of the clot over time.

The team found that despite a median interquartile range (IQR) platelet count of 77 (63–88) × 109/L in DVI patients, conventional coagulation tests and plasma fibrinogen levels were within the normal range. Subjects demonstrated hypercoagulability in 71.7% (38/53) in intrinsically activated thromboelastometry test (INTEM) and 54.7% (29/53) in extrinsically activated thromboelastometry test (EXTEM) in DVI patients. Fibrin-based thromboelastometry test (FIBTEM) analyses detected only 5.7% (3/53) with hypocoagulability among this population. The median (IQR) clotting time (CT), clot formation time (CFT) and maximum clot firmness (MCF) on INTEM were, respectively, 177 (160–207) seconds, 144 (108–178) seconds and 48 (42–52) mm. On EXTEM, median (IQR) CT, CFT and MCF were, respectively, 69 (65–78) seconds, 148 (126–198) seconds and 49 (44–55) mm.

The authors concluded that thromboelastometry impairment is highly prevalent in DVI patients with thrombocytopenia, particularly in INTEM and EXTEM analyses, while standard coagulation tests are normal in this setting, but clinical implications remain to be established. The study was published on January 19, 2017, in the journal BMC Infectious Diseases.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more