We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Electronics-Enhanced Microfluidic Chip Counts and Characterizes Cells or Particles

By LabMedica International staff writers
Posted on 02 May 2016
Print article
Image: A hybrid microfluidic chip (held by Dr. Fatih Sarioglu) uses a simple circuit pattern to assign a unique seven-bit digital identification number to each cell passing through the channels (Photo courtesy of the Georgia Institute of Technology).
Image: A hybrid microfluidic chip (held by Dr. Fatih Sarioglu) uses a simple circuit pattern to assign a unique seven-bit digital identification number to each cell passing through the channels (Photo courtesy of the Georgia Institute of Technology).
In a proof-of-concept study, a team of electrical and computer engineers demonstrated the ability of an electronics-enhanced microfluidic chip to characterize and count ovarian cancer cells.

While numerous biophysical and biochemical assays have been developed that rely on spatial manipulation of particles or cells as they are processed on lab-on-a-chip devices, analysis of spatially distributed particles on these devices typically requires microscopy, which negates the cost and size advantages of microfluidic assays.

Investigators at the Georgia Institute of Technology (Atlanta, USA) have combined microfluidics with electronic sensor technology to produce a lab-on-a-chip device that can determine the location, size, and speed of cells moving through the microfluidic channels. The information for each individual cell is stored and then used as the basis for automated cell counting and analysis.

The underlying principle enabling cell identification is code division multiple access (CDMA), which is used by cellular telephone networks to separate the signals from each user. The innovative on-chip version is called microfluidic CODES. The CODES method relies on a grid of micron-scale electrical circuitry located in a layer beneath the four-channel microfluidic chip. Current flowing through the circuitry creates an electrical field in the microfluidic channels above the grid. When a cell passes through one of the microfluidic channels, it creates an impedance change in the circuitry that signals the cell’s passage and provides information about the cell’s location, size, and the speed at which it is moving through the channel. The packet of information generated for each cell is assigned a unique seven-bit identifier number that is stored for analysis.

As a proof of principle, the investigators use this technology to detect human ovarian cancer cells in four different microfluidic channels fabricated using soft lithography. In this exercise more than a thousand ovarian cancer cells were tracked with an accuracy rate of better than 90%.

“We are digitizing information about the sorting done on a microfluidic chip,” said senior author Dr. Fatih Sarioglu, assistant professor of electrical and computer engineering at the Georgia Institute of Technology. “By combining microfluidics, electronics, and telecommunications principles, we believe this will help address a significant challenge on the output side of lab-on-a-chip technology.”

“We have created an electronic sensor without any active components,” said Dr. Sarioglu. “It is just a layer of metal, cleverly patterned. The cells and the metallic layer work together to generate digital signals in the same way that cellular telephone networks keep track of each caller’s identity. We are creating the equivalent of a cell phone network on a microfluidic chip. Our technique could turn all of the microfluidic manipulations that are happening on the chip into quantitative data related to diagnostic measurements.”

The CODES-based lab-on-a-chip was described in the March 29, 2016, online edition of the journal Lab on a Chip.

Related Links:
Georgia Institute of Technology

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.