By LabMedica International staff writers
Posted on 27 Aug 2014
Print article
Image: The Jasco UV/Vis 530 spectrophotometer (photo courtesy of Jasco Analytical Instruments).
Image: The Jasco UV/Vis 530 spectrophotometer (photo courtesy of Jasco Analytical Instruments).
Image: The Agilent 1100 high-performance liquid chromatography (Photo courtesy of Agilent Technologies).
Image: The Agilent 1100 high-performance liquid chromatography (Photo courtesy of Agilent Technologies).
A new colorimetric procedure has been described for the visible-range spectrophotometric analysis of glutathione (GSH) in microvolumes of blood collected by fingerstick and validated by reliable high-performance liquid chromatography.

GSH deficiency predisposes to oxidative damage which is thought to contribute to onset and progression of many disease states; while conversely, elevated GSH levels generally confer resistance to oxidative stress as observed in many types of cancer cells.

Clinical biochemists at the University of Siena (Italy) took both venipuncture sample and fingerstick blood samples from 23 healthy subjects, 14 females and 9 males, age range from 27 to 35 years. At screening, they all had normal physical examination and laboratory analyses including blood counts, lipid profile, comprehensive metabolic panel, uric acid, iron, urinalysis and urine electrolytes.

The analysis of GSH in blood collected by fingerstick after processing was measured in the clear supernatant by using a modification of a colorimetric method, using 5,5′-dithio-bis(2-nitrobenzoic acid) , which is also known as Ellman's reagent or DNTB. Reaction between GSH and DTNB was analyzed at 412 nm wavelength by a Jasco UV/Vis 530 spectrophotometer (Easton, MD, USA). Analysis of GSH by HPLC was performed by chromatographic separation performed on a Zorbax Eclipse XDB-C18 column (Agilent Technologies; Santa Clara, CA, USA) absorbance detection was carried out on an Agilent 1100 instrument equipped with a diode detector.

In a group of 23 healthy subjects the GSH content in blood was determined by the micro-method to be 8.54 ± 0.11 nmol/mg hemoglobin. Linear regression analysis of the GSH concentrations determined by parallel analysis of the same samples with the reference HPLC method showed a satisfactory correlation between the two methods. These data indicate that the main feature of the new micro-method is its excellent precision and accuracy for blood GSH.

The authors concluded that the new HPLC-validated procedures for the determination of GSH in micro volumes of blood, that are collected by fingerstick in humans, sample volumes as low as 0.5 μL are suitable for analysis. Being minimally invasive, the fingerstick method can be used to monitor frequently GSH concentrations while avoiding the discomfort and possible adverse events associated with phlebotomy. The procedure is suitable for minimally invasive investigation of oxidative stress in peripheral blood. The study was published on August 1, 2014, in the Journal of Chromatography B.

Related Links:

University of Siena
Jasco
Agilent Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more