Blood Urea and Creatinine Stability Determined for Chemistry Analyzer

By LabMedica International staff writers
Posted on 17 Dec 2013
Print article
Advia 1800 Chemistry Analyzer System (Photo courtesy of Siemens).
Advia 1800 Chemistry Analyzer System (Photo courtesy of Siemens).
Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on some clinical chemistry analyzers.

A general quality assurance program in clinical chemistry laboratories is an essential part of monitoring the stabilities of determinations on what are commonly known as stat analytes, including sodium, potassium, chloride, bicarbonate, calcium, glucose, blood urea nitrogen (BUN), and creatinine.

Medical laboratory scientists at the New York Harbor Veteran Affairs Medical Center (Brooklyn, NY, USA) investigated the reproducibility of creatinine values, by determining the serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58 to 7.8 mg/dL). They determined BUN and creatinine values, using the glutamate dehydrogenase linked enzyme assay system and the Jaffe method, respectively.

Determination of all values was performed on the Siemens Advia 1800 chemistry analyzer (Siemens Healthcare; Tarrytown, NY, USA) using the method for creatinine, which uses the formation of a complex of creatinine with picric acid, and for BUN values urease-catalyzed release of ammonia was measured by the glutamate dehydrogenase system. The creatinine values were determined concurrently with serum blood urea nitrogen (BUN) determinations, range 6.0 to 84.4 mg/dL, as these two analytes are used together in evaluation of renal function.

The scientists found that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CV). One sample with relatively high CV of 10.6% for creatinine was found to have an initial value of 1.1 mg/dL, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dL, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present.

The authors concluded that the precision of the serum BUN assays on the Advia 1800 analyzer is quite high over the prolonged time period of 15 days. The same conclusion applies to serum creatinine assay results on this analyzer with the caveat that borderline values can show less precision-making evaluation of renal function more difficult. The study was published on November 11, 2013, in the Journal of Clinical Laboratory Analysis.

Related Links:

New York Harbor Veteran Affairs Medical Center
Siemens Healthcare
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.