We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Image Cytometry Measures Mononuclear Cell Concentration

By LabMedica International staff writers
Posted on 12 Feb 2013
Print article
A rapid fluorescence-based image cytometry system has been utilized for brightfield and fluorescence imaging analysis of cellular characteristics.

The viability and concentration of isolated peripheral blood mononuclear cells (PBMCs) are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer, but red blood cell (RBC) contamination can be an issue.

Scientists at the Nexcelom Bioscience Laboratories, (Lawrence, MA, USA) compared their Cellometer Vision instrument with both manual counting and automatic method for accurately measuring the concentration of PBMCs in prepared blood samples. Fifteen freshly isolated samples were stained with acridine orange and propidium iodide (AO/PI) to identify RBC contamination. The five different methods were manual counting of TB-stained PBMCs in hemacytometer; manual counting of PBMCs in brightfield images; manual counting of acetic acid lysing of RBCs with TB-stained PBMCs; automated counting of acetic acid lysing of RBCs with PI-stained PBMCs; and AO/PI dual staining method.

Each of the 15 samples measured was categorized into low, medium, or high RBC contamination. Five samples showed less than 10% of RBC contamination, six samples showed 10% to 40% of RBC contamination, and four samples showed RBC contamination greater than 40%. The total particles counted in brightfield increased due to the addition of RBCs, while AO/PI staining showed consistent measurement of PBMCs, which again demonstrated the robustness of the method despite RBC contamination. Although inherent RBC contaminants may have existed in the sample, the purpose was to observe the increasing difference between fluorescently stained nucleated cells and total brightfield cell count including RBCs.

The authors concluded that fluorescence-based image cytometry can be utilized to eliminate the RBC-induced error in patient samples, which can improve accuracy and efficiency of PBMC measurement. Cellometer image cytometry has also demonstrated fluorescence-based cell population analysis such as apoptosis detection, cell cycle, as well as surface marker labeling. The system can be used to perform immunophenotyping of collected PBMCs, and can quickly characterize incoming patient samples, further simplifying PBMC characterization protocol. The study was published in the February 2013 issue of the Journal of Immunological Methods.

Related Links:
Nexcelom Bioscience

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.