Stability of Hematological Parameters Tested In Blood Collection Systems

By LabMedica International staff writers
Posted on 26 Oct 2010
Print article
The integrity of a hematological sample is known to depend on time and temperature and the measurement technique has already been found to have an impact on stability.

Two specimen tubes containing an anticoagulant were tested for their affect on the stability of hematological parameters overtime. Full blood count and reticulocyte hematological analyses were conducted on a Beckman Coulter LH750 hematology analyzer (Beckman Coulter, Inc, Brea, CA, USA), at multiple time points up to 72 hours.

The two blood collection systems tested were the Vacutainer from Becton Dickinson, (BD; Franklin Lakes, NJ USA) and the Monovette from Sarstedt Inc., (Newton, NC, USA). In a recent study carried out by Icon Development Solutions (Manchester, UK), twenty healthy volunteers (10 males, 10 females) were recruited. No restrictions were placed on these volunteers. A total of 36.9 mL blood was taken from each volunteer, collected using a cannula into seven 2.7 mL ethylenediaminetetraacetic acid (EDTA) Sarstedt Monovettes and four 4.5 mL EDTA BD Vacutainers. Both types of tube are plastic and contain tri-potassium (K3) EDTA as an anticoagulant. Becton Dickinson tubes contain 7.2 mg K3 EDTA in a 4 mL tube; Sarstedt tubes contain sufficient K3 EDTA to achieve a concentration of 1.2-2 mg EDTA/mL blood, with a maximum dilution effect of 1%.

All parameters matched or exceeded Beckman Coulter stated stability values, with both Sarstedt and BD tubes showing remarkably similar levels of stability for all parameters. The exceptions were that mean platelet volume (MPV) was only stable for 18 hours in BD tubes and 24 hours in Sarstedt tubes, and neutrophils (NE) were stable for 72 hours in BD tubes, but only 48 hours in Sarstedt tubes. However, it was noted that the degradation of the Sarstedt samples appears to be more predictable and follows a much more linear pattern. Accurate full blood count results can be obtained on samples up to 48 hours, provided that the samples are stored in a refrigerator. The tube type was found to have minimal impact on the stability of hematological samples. The study was published in October 2010 in the British Journal of Biomedical Science.

Related Links:
Beckman Coulter
Becton Dickinson
Sarstedt
Icon Development Solutions

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.