Reproducibility Of Stored Serum Potassium Values Analyzed

By LabMedica International staff writers
Posted on 29 Jun 2016
Print article
Image: The ADVIA 1800 clinical chemistry system (Photo courtesy of Siemens Healthcare).
Image: The ADVIA 1800 clinical chemistry system (Photo courtesy of Siemens Healthcare).
The reproducibility of serum potassium values in serum from blood samples stored for increasing times prior to centrifugation and analysis has been investigated.

The goal of the investigation was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Abnormal serum potassium levels are indicative of many diseases including kidney failure and hyperkalemic periodic paralysis.

Scientists in the department of Pathology at the SUNY Downstate Medical Center (Brooklyn, NY, USA) collected from 20 participants who donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hours on the Advia 1800 autoanalyzer (Siemens Healthcare, Erlangen, Germany).

The scientists found that the Coefficients of Variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3% ± 2%. Statistical testing of the means for all 20 samples indicated that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were less or equal to 5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a four hour value that was within the reference or normal range of 3.5 to 5 mEq/L. Overall, most samples were found to have reproducible levels of serum potassium.

The authors concluded that serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least four hours prior to analysis. However, some samples can exhibit significant fluctuations of values. The study was published on May 30, 2016, in the Journal of Clinical Laboratory Analysis.

Related Links:
SUNY Downstate Medical Center
Siemens Healthcare
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.