Rapid Method Developed for Direct Antimicrobial Susceptibility Testing

By LabMedica International staff writers
Posted on 23 Aug 2016
Print article
Image: The Alfred 60AST bacterial identification system with antibiogram (Photo courtesy of Alifax).
Image: The Alfred 60AST bacterial identification system with antibiogram (Photo courtesy of Alifax).
Rapid identification (ID) and antimicrobial susceptibility testing (AST) of the causative agent(s) of bloodstream infections (BSI) are essential for the timely selection of an appropriate antimicrobial therapy, which may result in a better outcome for patients and contribute to combat the emergence of antimicrobial resistance.

A method has been established able to provide rapid AST results, further referred to as direct AST. To this aim, an approved system, initially conceived for urine screening, and for AST of bacterial isolates from urine was used. In order to adapt the system to rapid AST from positive blood cultures, two different protocols, protocol 1 (PR1) and protocol 2 (PR2), were evaluated.

Scientists at the University of Pisa (Italy) and their collaborators inoculated blood specimens from patients admitted to the Pisa University Hospital in the period July-December 2014, into blood culture bottles and transferred to the Bactec FX instrument (Becton Dickinson, Franklin Lakes, NJ, USA) for monitoring bacterial growth. From each patient, only the first positive blood culture (BC) apparently monomicrobial at the Gram staining was included in this study.

BC positive at the Bactec FX instrument were subjected to Gram staining and subcultured onto appropriate solid media. Isolated colonies were identified by MALDI-TOF (Bruker Daltonics, Bremen, Germany) and AST was performed by Vitek 2 (bioMérieux, Marcy l’Étoile, France). Direct AST of bacteria was performed by a Alfred 60AST automated bacterial culture device (Alifax SpA, Polverara, Italy) and carried out using two different protocols, PR1 and PR2. By PR1, bacteria were recovered from positive BC by serum separator tubes or by PR2 after a short-term subculture in liquid medium.

The direct MALDI-TOF method concordantly identified with the current method 97.5% of the Gram-negative bacteria and 96.1 % of the Gram-positive cocci contained in monomicrobial blood cultures. The direct AST by PR1 and PR2 for all isolate/antimicrobial agent combinations was concordant/correct with the current method for 87.8% and 90.5 % of Gram-negative bacteria and for 93.1% and 93.8 % of Gram-positive cocci, respectively. In particular, 100% categorical agreement was found with levofloxacin for Enterobacteriaceae by both PR1 and PR2, and 99.0% and 100 % categorical agreement was observed with linezolid for Gram-positive cocci by PR1 and PR2, respectively. There was no significant difference in accuracy between PR1 and PR2 for Gram-negative bacteria and Gram-positive cocci.

The authors concluded that their newly described method seems promising for providing accurate AST results. Most importantly, these results would be available in a few hours from blood culture positivity, which would help clinicians to promptly confirm or streamline an effective antibiotic therapy in patients with bloodstream infections. The study was published on August 12, 2016, in the journal BMC Microbiology.

Related Links:
University of Pisa
Becton Dickinson
Bruker Daltonics
bioMérieux
Alifax

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.