We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Rapid Influenza Detection Tests Evaluated for Viral Antigens

By LabMedica International staff writers
Posted on 01 Dec 2016
Print article
Image: The rapid influenza detection test Quick Navi-Flu (Photo courtesy of Otsuka Pharmaceutical).
Image: The rapid influenza detection test Quick Navi-Flu (Photo courtesy of Otsuka Pharmaceutical).
Reverse transcriptase polymerase chain reaction (RT-PCR) has a high sensitivity and a high specificity for the rapid diagnosis of influenza infection; however, the high cost and necessity of specialized equipment have limited the use of RT-PCR in the clinical setting.

Immunochromatography-based rapid influenza virus antigen tests, in which the result appears within 15 minutes, have been used for the early diagnosis of influenza in the clinical setting in Japan. Rapid influenza detection tests (RIDTs) equipped with an instrument-based fluorescence reader system has recently been developed, and their performances have been validated.

Scientists at the Tokyo Medical University (Japan) enrolled a total of 123 participants consisting of 53 men (43.1%) and 70 women (56.9%). The mean age of the patients was 35.1 years (range 20–74 years). The median time to visiting the hospital after illness onset was 26.2 hours (ranging from a few hours to five days). The study was performed from December 2013 to March 2014. Nasopharyngeal swab specimens were collected by performing original swab samplings, which were composed of three swabs.

After collecting the specimens from the participants, the swabs were separated for the tests. One swab was transferred in viral transport medium for virus isolation; the other two swabs were used for the rapid influenza virus antigen detection tests. In this study, the new RIDT GOLD SIGN FLU (Morinaga Milk Industry Co., Ltd, Tokyo, Japan) and Institute of Immunology Co., Ltd, Tokyo, Japan) and the existing immunochromatography-based RIDT Quick Navi-Flu (Otsuka Pharmaceutical Co., Ltd, Tokyo, Japan) were evaluated as compared to viral isolation as the gold standard method.

Among the 123 patients from whom nasopharyngeal swab specimens were collected, 59 tested positive by viral isolation as the gold standard method, 38 with influenza A; 21 with influenza B. For GOLD SIGN FLU, the sensitivities were 73.7% and 81.0%, and the specificities were 97.6% and 98.0% for influenza A and B, respectively. For Quick Navi-Flu, the sensitivities were 86.8% and 85.7%, and the specificities were 98.8% and 100% for influenza A and B, respectively. The time to the appearance of the line on the test strip was less than three minutes for influenza A and less than two minutes for influenza B with both RIDTs in more than 90% of cases.

The authors concluded that GOLD SIGN FLU was useful for diagnosing influenza A, and the result was readily available for influenza B particularly among adult patients. Quick Navi-Flu showed better sensitivities and specificities than GOLD SIGN FLU. The study was published in the November 2016 issue of the International Journal of Infectious Diseases.

Related Links:
Tokyo Medical University
Morinaga Milk Industry
Institute of Immunology
Otsuka Pharmaceutical
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.