Features | Partner Sites | Information | LinkXpress
Sign In
RANDOX LABORATORIES
GLOBETECH PUBLISHING LLC
FOCUS DIAGNOSTICS, INC.

Screening Tool Evaluated for Urinary Infection Diagnosis

By Labmedica International staff writers
Posted on 31 Oct 2013
Image: The UriSed automatic urine sediment analyzer (Photo courtesy of 77 Elektronika Kft).
Image: The UriSed automatic urine sediment analyzer (Photo courtesy of 77 Elektronika Kft).
A quantitative urine culture is essential for the final diagnosis of urinary tract infection (UTI), but it is time-consuming and an expensive procedure.

Effective screening tests would be a promising alternative to provide immediate results for the clinician and eliminate unnecessary culturing for most of the negative samples.

Laboratory scientists at the University of Campinas (Brazil) evaluated 1,379 clean-catch midstream urine samples from inpatients and outpatients. This included 1,006 females and 373 males, age ranging from two months to 90 years, with a median age of 41 years. Three hundred ninety-nine patients (29%) had renal diseases, including kidney transplantation and functional or anatomical abnormalities of the urinary system and 8% of the cases were pregnant women.

All samples were submitted to automated sediment analysis called UriSed (77 Elektronika Kft; Budapest, Hungary) and quantitative urine culture on Cystine-Lactose-Electrolyte-Deficient Agar (CLED) (Becton Dickinson; Franklin Lakes, NJ, USA). The cut-off values for leukocyturia and significant bacteriuria were established by comparing the results obtained by UriSed and by urine culture.

From all the 1,379 analyzed urine samples, 664 of these (48%) were classified as positive for UTI by UriSed and 715 (52%) samples were classified as negative. Urine culture was positive in 13% of the samples (183/1,379). As expected, Escherichia coli was the most common microorganism isolated (84/183), followed by Klebsiella spp. (16/183) and Proteus spp. (8/183).

The sediment analyzer detected leukocyturia and/or significant bacteriuria with sensitivity of 97%, specificity of 59%, positive predictive value of 27%, negative predictive value of 99%, and accuracy of 64% at cutoff values of bacteria count equal to or greater than 12.6 elements/ high-power field (hpf) and white blood cells (WBC) equal to or greater than 6 cells/hpf. These data suggest a potential 52% reduction of unnecessary urine cultures.

The authors concluded that the UriSed system appears to be an efficient tool to rule out UTI with high sensitivity (97%) and low rate of false-negative results (1%) and thus reduce unnecessary urine cultures. However, a positive screen does not necessarily indicate UTI and should be confirmed by urine culture. The study was published on October 21, 2013, in the journal Clinica Chimica Acta.

Related Links:

University of Campinas
77 Elektronika Kft 
Becton Dickinson



KARL HECHT GMBH & CO KG
77 ELEKTRONIKA
DIASYS DIAGNOSTIC SYSTEMS

Channels

Genetic Tests

view channel

Padlock Probe Assay Rapidly Detects Cardiac Disease Gene Mutations

A recent paper described a novel next generation sequencing (NGS) assay for detecting cardiac disease gene mutations with improved accuracy, flexibility, turnaround time, and cost. By using double-stranded DNA probes (complementary long "padlock" probes or cLPPs), investigators at Stanford University (Palo Alto, CA,... Read more

Hematology

view channel
Image: Immunochemistry of bone marrow biopsy from an acute myeloid leukemia patient showing sheets of CD34 positive cells; corresponding bone marrow aspirate showed only 20% blasts (Photo courtesy of All India Institute of Medical Sciences).

Immunohistochemistry Assesses Early Response in Acute Myeloid Leukemia

Acute myeloid leukemia (AML) is a heterogeneous disease with respect to prognosis and early response assessment has an established role as predictor of remission rate, and overall and disease-free survival.... Read more

Industry News

view channel

Distribution Agreement to Uniquely Improve Automated Hemostasis Diagnostics

A new, exclusive-distributer agreement will lead to creating a unique high-performance hemostatis work cell by connecting a laboratory automation system (LAS) from Thermo Fisher Scientific (Waltham, MA, USA) with a hemostasis testing LAS from Instrumentation Laboratory (IL; Bedford, MA, USA). The agreement between IL... Read more
 
Copyright © 2000-2015 Globetech Media. All rights reserved.