Different D-Dimer Values Compared for Venous Thromboembolism Risk

By LabMedica International staff writers
Posted on 27 Sep 2015
Print article
Image: The highly-sensitive automated D-Dimer assay VIDAS D-Dimer Exclusion II (Photo courtesy of bioMérieux).
Image: The highly-sensitive automated D-Dimer assay VIDAS D-Dimer Exclusion II (Photo courtesy of bioMérieux).
D-dimer assays are generally evaluated according to cutoff points calibrated for of venous thromboembolism (VTE) exclusion and used to estimate the individual risk of recurrence after a first idiopathic event VTE.

The increase in age-dependent D-dimer levels has long been seen as a problem for the use of these assays in the work-up for VTE exclusion, and the assays performs poorly in the elderly population when traditional cutoff levels are adopted. Different cutoff systems have therefore been proposed and prospectively investigated to rule out pulmonary embolism.

Scientist at the University Hospital of Bologna (Italy) and their colleagues screened a total of 1,010 patients, whose index VTE event was idiopathic or associated with weak risk factors, and were included in the management protocol. Persistently negative D-dimer results were recorded in 528 patients (52.8%) who permanently interrupted anticoagulation and were followed up for a maximum of two years. In contrast, the remaining 482 patients had positive D-dimer results, and at the moment of their first positive result, were recommended to continue or resume anticoagulant therapy and followed by their anticoagulation clinic.

D-dimer levels were measured using the following commercial quantitative assays: VIDAS D-dimer Exclusion (bioMerieux; Lyon, France), Innovance D-DIMER (Siemens; Deerfield, IL, USA), HemosIL D-dimer HS or HemosIL D-dimer (Instrumentation Laboratory; Milan, Italy), and (v) STA Liatest D-dimer (DiagnosticaStago; Asnieres-sur-Seine, France). As cutoff values for negative/positive results, the centers used those specific for the assay, distinguishing those with results expressed as fibrinogen equivalent units (FEU) or non-FEU (D-dimer units) and for age and gender.

The predetermined cutoff levels for each assay, specific for age (lower in subjects less than 70 years), and gender (because it is lower in males), were used. In young subjects, the D-dimer-ULtrasonography in Combination Italian Study (DULCIS) low cutoff levels resulted in half the recurrent events that would have occurred using the other criteria. In elderly patients the DULCIS results were similar to those calculated for the two age-adjusted criteria. The adoption of traditional VTE exclusion criteria would have led to positive results in the large majority of elderly subjects without a significant reduction in the rate of recurrent event.

The authors concluded that the low cutoff levels adopted in the DULCIS study for young subjects resulted in more young patients who resumed anticoagulation with subsequent increased protection from recurrent events in this population that is at high risk of recurrence. In elderly patients, the high DULCIS cutoff points led to results similar to those calculated for the two age-adjusted criteria; the adoption of VTE exclusion criteria would have led to positive results in the large majority of subjects, without a significant reduction in the rate of recurrent event. The study was published on September 12, 2015, in the journal International Journal of Laboratory Hematology.

Related Links:

University Hospital of Bologna
bioMérieux
Siemens


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.