Platelet Antibody Specificity Analyzed by Different Tests

By LabMedica International staff writers
Posted on 09 Jun 2015
Print article
Image: Scanning electron micrograph of activated platelets (Photo courtesy of Bayer).
Image: Scanning electron micrograph of activated platelets (Photo courtesy of Bayer).
The detection of platelet antibodies plays a crucial role in the diagnosis of immunologic platelet disorders such as fetal/neonatal alloimmune thrombocytopenia (FNAIT) or refractoriness to platelet transfusions, influencing further therapeutic management.

The gold standard analysis for the determination of platelet antibodies, the “monoclonal antibody immobilization of platelet antigens” assay is restricted to specialized reference laboratories due to the laborious efforts involved and the consequent need for freshly prepared test platelet.

Hematologists at the Medical University of Graz (Austria) analyzed serum samples from 1,234 patients with a median age of 58.2 years and 573 were female and 661 male. The serum samples were tested for Human Leukocyte Antigen (HLA) or platelet-specific antibodies. The scientists routinely use two commercially available test methods, an antigen capture ELISA and a solid-phase assay. For the confirmation and specification of anti-HLA class I antibodies, a complement-dependent lymphocytotoxicity test is additionally performed.

All serum samples were analyzed by enzyme-linked immunosorbent assays (ELISA), either Lifecodes PAKPLUS or PAK12 (Gen-Probe; Waukesha, WI, USA), and by a solid-phase assay (Capture-P Ready Screen, Immucor Inc.; Norcross, GA, USA), and in specified cases by a specific lymphocytotoxicity test (LCT, Bio-Rad Medical Diagnostics GmbH; Dreieich, Germany). The LCT was performed in cases of clinically suspected or, by the described assays detected, HLA class I antibodies.

Platelet antibodies were detected in 366 of 1,234 samples (29.7%). In 70.3% concordant negative, but only in 8.4% concordant positive results were obtained with both the methods; 185 of 1,053 in the solid-phase assay negative samples were positive in the ELISA (15.0%). In samples positive in both methods, most antibodies reacted against HLA class I antigens. Glycoprotein (GP) specific platelet antibodies were more frequently detectable in the ELISA than in the solid-phase assay, whereas weakly positive results have to be interpreted cautiously.

The authors concluded that because ELISA, solid-phase assay, and LCT showed highly divergent results and only for detecting soluble platelet antibodies, and due to several limitations. The additional analysis by the “monoclonal antibody-specific immobilization of platelet antigen” (MAIPA) assay is highly recommended. The study was published on May 5, 2015, in the Journal of Clinical Laboratory Analysis.

Related Links:

Medical University of Graz 
Gen-Probe 
Immucor Inc. 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.