Fragmented Red Blood Cell Measurement Automated

By Labmedica International staff writers
Posted on 02 Jul 2012


Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
The laboratory diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult.

The detection of schistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of schistocytes is still problematic with wide inter-observer variations.

Hematologists at the University Hospital (Nancy, France) conducted studies comparing automated and microscopic counts of Fragmented Red Blood Cells (FRC) and schistocytes. The data came from the day-to-day analysis of more than 90,000 peripheral blood (PB) samples for 10 years in four centers. More than 900 patients were examined because of a clinical suspicion of TMA and 17 samples were derived from preterm newborns who were supposed to give the highest FRC counts among nonpathologic samples.

FRC were counted by automated direct measurement using the two automated analyzers (ABCC): the ADVIA 120 analyzer (Siemens; Tarrytown, NY, USA) and the XE-2100 analyzer (Sysmex; Kobe, Japan). Schistocyte counting was carried out from May-Grünwald-Giemsa-stained PB smears. The reference range for FRC was less than 0.3% for the ADVIA and less than 0.5% for the Sysmex XE-2100.

The correlation coefficient for Siemens devices was around 0.7. The main problem resulted from an overestimation of FRC as compared to schistocytes from 0.4% to 0.5% for a count of schistocyte ranging from 0% to 1.5%. Conversely, the scientists observed an underestimation of FRC as compared to schistocytes subsequent to this 1.5% threshold. For the Sysmex XE-2100 counter, the overestimation of the FRC was more pronounced, at less 0.8%, and increased slightly with high schistocyte percentages. The presence of FRC below a threshold determined at 1% for both automated analyzers had a negative predictive value (PV) close to 100% to exclude the presence of schistocyte on the blood smear, but in relationship with a poor positive PV value.

The authors concluded that that systematic quantification of FRC might improve the laboratorians' ability to exclude samples with schistocytes. This should be especially useful among patients in whom TMA diagnosis is suspected. However, several limitations deserve consideration such as few false-negative FRC counts in a context of macrocytosis, great lack of specificity. Hence, a PB smear examination was still advised for the validation of the count if needed. The study was published on June 14, 2012, in the International Journal of Laboratory Hematology.

Related Links:

University Hospital
Siemens
Sysmex





Random Access Analyzer
Random Access Analyzer
Automimmune Disease Marker
Automimmune Disease Marker
Urine Analyzer
Urine Analyzer

More Products

Latest Hematology News

LinkXpress
Click for LinkXpress
Reader Inquiry Service
Enter code to receive information:
Where I can find code?
Featured Whitepaper
SIEMENS DIAGNOSTICS :
Siemens Healthcare Diagnostics Anti-CCP: A Clinical Evaluation Whitepaper

Download Whitepaper
Events
ELA – European Lab Automation congress
06 Jun 2013 - 07 Jun 2013


European Human Genetics Conference 2013
08 Jun 2013 - 11 Jun 2013


8th Forum on Oxidative Stress and Aging
12 Jun 2013 - 14 Jun 2013


More events
GLOBETECH PUBLISHING
Latest Issue

View Digital Edition
Subscribe / Renew
77 ELEKTRONIKA
DIASOURCE
AACC
ALTO MARKETING LIMITED
KARL HECHT GMBH & CO KG
GREINER-BIO-ONE
BioPorto Diagnostics
  labmedica.com Copyright © 2000-2013 Globetech Media. All rights reserved.
Privacy Policy