Capillary Zone Electrophoresis Developed for Rapid Determination of Thalassemia

By LabMedica International staff writers
Posted on 10 Jun 2015
Print article
Image: The P/ACE MDQ Capillary Electrophoresis System (Photo courtesy of Beckman Coulter Inc.).
Image: The P/ACE MDQ Capillary Electrophoresis System (Photo courtesy of Beckman Coulter Inc.).
A capillary zone electrophoresis (CZE) method has been developed for human globin determination in the diagnosis of thalassemia and hemoglobin variants as analysis of globin chains is an important aspect of thalassemia diagnostics.

Thalassemia is an inherited autosomal recessive blood disorder characterized by the underproduction of globin chains as a consequence of globin gene defects, resulting in malfunctioning red blood cells and oxygen transport.

Medical scientists at the Southern Medical University (Guangzhou, China) evaluated an assay on blood samples obtained from anticoagulated whole blood from a total of 310 clinical samples consisting of 58 normal, 107 α-thalassemia silent/trait, 42 β-thalassemia carriers and 63 β-thalassemia major and β-thalassemia intermedia (β -TM/TI), and 40 others with various hemoglobinopathies.

Hemoglobin analysis was carried out using the high-performance liquid chromatography (HPLC, Variant II, Bio-Rad Laboratories; Hercules, CA, USA). Capillary zone electrophoresis (CZE) was performed using a P/ACE MDQ Capillary Electrophoresis System (Beckman Coulter Inc.; Fullerton, CA, USA) equipped with a 70 cm × 50 μm uncoated fused-silica capillary at 25 °C.

Distinct globin peaks were resolved in 17 minutes and coefficients of variation (CV) for migration time and areas ranged from 0.37% to 1.69% and 0.46% to 6.71%, respectively. Receiver operating characteristic (ROC) curve analysis of the α/β area ratios gave 100% sensitivity and specificity for indicating β-TI/TM, and 100% sensitivity and 97.4% specificity for Hb H disease. Hemoglobin G-Honolulu (Hb G-Honolulu) and Hb Westmead (Hb WS) were successfully detected using this CZE method.

The authors concluded that they had successfully developed a simple, rapid, high-resolution CZE method for the separation of globin chains using highly acidic buffer and uncoated capillaries. Using this method, α-, β- and γ-chains, and αWS and αG Honolulu  chains were successfully separated within 17 minutes, indicating suitability for routine clinical applications. The migration times and globin chain peak areas were highly reproducible; although not as rapid as existing high-throughput HPLC techniques. This CZE method may provide an attractive complementary and/or confirmatory approach. The study was published in the June 2015 issue of the journal Blood Cells Molecules and Diseases.

Related Links:

Southern Medical University 
Bio-Rad Laboratories  
Beckman Coulter Inc.


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.