Micropump Developed for Lab-On-A-Chip Disease Diagnosis

By LabMedica International staff writers
Posted on 18 Sep 2014
Print article
Image: An acoustically powered pumping device with 250 micron long oscillating structures driven by a piezoelectric transducer mounted on a glass slide shown next to US copper penny (Photo courtesy of Po-Hsun Huang and Tony Jun Huang).
Image: An acoustically powered pumping device with 250 micron long oscillating structures driven by a piezoelectric transducer mounted on a glass slide shown next to US copper penny (Photo courtesy of Po-Hsun Huang and Tony Jun Huang).
A reliable, inexpensive, programmable pump is a crucial feature for lab-on-a-chip devices that could make the diagnosis of many global life-threatening diseases easy and affordable.

An acoustofluidic pump powered by a piezoelectric transducer has been developed that utilizes the acoustic streaming effects generated by the oscillation of tilted sharp-edge structures.

Bioengineers and scientists at The Pennsylvania State University, (University Park, PA, USA) developed the pump which works by oscillating a series of thin sharp-edge structures hundreds of micrometers in length that have been constructed onto the sidewall of a microfluidic channel made of polydimethylsiloxane (PDMS), a widely used polymer. A miniaturized piezoelectric transducer, similar to the kind used in medical ultrasound, is the source of the oscillations.

The acoustofluidic pump was made by bonding a single-layer PDMS channel onto a single glass slide and attaching a piezoelectric transducer (Murata Electronics; Smyrna, GA, USA) adjacent to it using a thin layer of epoxy. To demonstrate the pumping behavior, the PDMS channel was designed to be a rectangular recirculating (in a counter-clockwise direction) channel composed of four portions: left channel, right channel, upper channel, and lower channel. The lower channel, referred to as the pumping region, was designed with 20 tilted sharp-edge structures on its sidewall, 10 on each side, while the other three channels were straight channels without any structures. The piezoelectric transducer, activated by amplified sine wave signals from a function generator (Tektronix; Beaverton, OR, USA) and an amplifier was used to acoustically oscillate the sharp-edge structures to generate acoustic streaming effects.

Tony Jun Huang, PhD, an engineering professor and senior author of the study, said, “Our pump is quite unique. It’s reliable and programmable, with a minimum of hardware, yet highly precise. The flow rates can be tuned across a wide range, from nanoliters per minute to microliters per minute. The permanent equipment for the total lab-on-a-chip system, including off-the-shelf electronics, could cost as little as about USD 25.00 to make, and the disposable chip could cost as little as USD 0.10. Although slightly more expensive than paper-based diagnostics, the system is far more versatile and precise, enabling quantitative analysis of, for example, human immunodeficiency virus (HIV), hepatitis, cancer, infectious diseases, cardiovascular diseases.” The study was published on September 4, 2014, in the journal Lab-on-a-chip.

Related Links:

The Pennsylvania State University
Murata Electronics 
Tektronix  


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.