First US FDA-Cleared Dengue Test Independently Evaluated for Detection Quality

By LabMedica International staff writers
Posted on 16 Jul 2013
Print article
Image: The dengue virus (DENV) Detect IgM Capture ELISA from InBios (Photo courtesy of Inbios).
Image: The dengue virus (DENV) Detect IgM Capture ELISA from InBios (Photo courtesy of Inbios).
Researchers have now reported results from a first evaluation of the FDA-cleared assay for diagnosis of dengue virus infection in patients with suggestive clinical symptoms.

A study from the laboratory of Prof. Vivek R. Nerurkar at the University of Hawaii at Manoa (UHM; Honolulu, Hawaii, USA) provides the first independently funded evaluation of the InBios "DENV Detect IgM Capture ELISA", a rapid in vitro assay based on technology patented by the US Centers for Disease Control and Prevention (CDC; Atlanta, GA, USA). The assay, produced by Inbios International, Inc. (Seattle, WA, USA), is currently the only commercially available dengue infection assay cleared by the the US Food and Drug Administration (FDA; Silver Spring, MD, USA).

Diagnostic testing for dengue virus (DENV) infection is often time-consuming and complicated. The current study provides a comparative evaluation of the rapid (about five hours) InBios assay and a 2–3 day in-house "gold-standard" assay, and discusses some of the complicating factors. Well-characterized clinical serum samples obtained from 79 dengue-infected patients or suspected cases were performance-tested for qualitative detection of anti-DENV IgM antibodies, mainly in terms of sensitivity and specificity. The serum samples were collected from Hawaii, Vietnam, Niue, Singapore, and American Samoa, where dengue outbreaks have occurred in the past. Samples with equivocal results were repeated in duplicate, and samples that remained equivocal were further examined (e.g., using plaque reduction neutralization test (PRNT) where sufficient sample serum was available). Inclusion of positive as well as negative antigens was critical for interpretation of the results, as they detect background, nonspecific reactivity.

Sensitivity and specificity of InBios ELISA compared to the in-house "gold standard" ELISA were 92% and 94%, respectively. Out of the 79 serum samples tested, 22 samples were positive and 50 samples were negative by using both assays. Levels of agreement as defined by kappa values were also determined and the two assays showed near perfect agreement (κ = 0.87).

Overall, despite the relatively minor limitations of the study itself, the results indicate that the more rapid InBios DENV Detect IgM Capture ELISA is a reliable, sensitive, and specific serological test for detection of acute or recent dengue infections. It can also be used by public health laboratories for rapid confirmation of dengue cases during dengue outbreaks. Both tests show some cross-reactivity with West Nile and other closely related viruses and this must be considered, particularly when working in geographic regions where multiple flaviviruses co-circulate.

This study by Namekar M., et al. was published online ahead of print July 3, 2013, in the Journal of Clinical Microbiology.

Related Links:

UHM Dengue Test Publication Link
University of Hawaii at Manoa
InBios


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.