Cryptococcal Disease Determined by Lateral Flow Assays

By LabMedica International staff writers
Posted on 27 Aug 2014
Print article
Image: The Cryptococcal Antigen Lateral Flow Assay, the IMMY CrAg LFA (Photo courtesy of Immuno-Mycologics Inc).
Image: The Cryptococcal Antigen Lateral Flow Assay, the IMMY CrAg LFA (Photo courtesy of Immuno-Mycologics Inc).
Image: Cryptococcus neoformans yeast cells (photo courtesy of the Journal of Undergraduate Biological Studies).
Image: Cryptococcus neoformans yeast cells (photo courtesy of the Journal of Undergraduate Biological Studies).
The detection of subclinical cryptococcal disease using antigen screening among human immunodeficiency virus (HIV)-positive individuals presents a potential opportunity for prevention of both clinical disease and death.

Recently developed point-of-care cryptococcal antigen tests may be useful for screening, particularly in resource-limiting settings, so that patients with detectable cryptococcal antigen are identified and treated preemptively.

Scientists the Catholic University of Health and Allied Sciences (Mwanza, Tanzania) evaluate the utility of the point-of-care urine lateral flow assay (LFA) cryptococcal antigen test using two different diluents, compared to gold standard serum antigen testing, as a screening tool. Urine and serum of outpatients initiating antiretroviral therapy at two hospitals were tested for cryptococcal antigen.

The urine samples were screened for cryptococcal antigen using the CrAg LFA (Immuno-Mycologics Inc., Norman, OK, USA) in all patients using both a standard and a new test urine diluent. The LFA uses immunochromographic test strips that have been impregnated with monoclonal antibodies against capsular polysaccharide antigens common to fungi in the Cryptococcal species complex, including C. neoformans and C. gattii. The test strip is placed into the mixture and read after ten minutes at room temperature. The presence of two lines (test and control) on the test strip regardless of the intensity of the test line were interpreted as positive result, while the presence of a single control line was read as a negative result. The test takes about 10 minutes.

Among 140 patients screened, 10 (7.1%) had asymptomatic cryptococcal antigenemia with a positive serum cryptococcal antigen. Four of these 10 patients had cluster of differentiation 4 (CD4) counts between 100 and 200 cells/µL. The prevalence of cryptococcal antigen detected in urine using a standard (older) and a test (newer) diluent were 44 (31.4%) and 19 (13.6%). Compared to the new LFA diluent for urine cryptococcal antigen, the standard diluent had higher sensitivity, 100% versus 80%, but lower specificity, 74% versus 92%, using serum cryptococcal antigen as a gold standard.

The authors concluded that that HIV-positive outpatients with CD4 counts of less than 200, rather than 100 cells/µL, should be screened for asymptomatic cryptococcal antigenemia given its association with mortality if untreated. Agreement of the urine LFA with the serum LFA was not sufficient to recommend routine screening with urine LFA. The study was published on August 8, 2014, in the Journal of the International AIDS Society.

Related Links:

Catholic University of Health and Allied Sciences 
Immuno-Mycologics Inc. 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.