Newest Combination HIV Antigen-Antibody Assay Evaluated

By LabMedica International staff writers
Posted on 27 Feb 2013
Print article
Diagnostic tests capable of early detection represent the most effective means of preventing transmission of human immunodeficiency virus (HIV).

A fourth-generation antigen-antibody combination assay has been developed to allow earlier detection of seroconversion, and has increased sensitivity and improved specificity.

Scientists at the Innsbruck University Hospital (Austria) determined how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors.

The study was carried out at 12 centers in Europe, Thailand, and Australia. The Elecsys HIV combi PT assay (Roche Diagnostics; Penzberg, Germany) is performed according to the sandwich principle. The results are automatically determined by the Elecsys software that compares the signal produced from the sample with the cutoff value obtained during system calibration. The total assay time is 27 minutes.

A total of 14 seroconversion panels, comprising 135 samples were analyzed to determine how soon after a positive polymerase chain reaction (PCR) result the immunoassays could detect HIV infection. Samples were identified as positive by the Elecsys assay 4.9 days after a positive PCR result that had been predetermined, which was earlier than the 5.3 to 7.1days observed with other comparable assays. The analytical sensitivity of the Elecsys HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the other assays.

In addition, the assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. The assay demonstrated 100% specificity in patients with infections other than HIV, such as Cytomegalovirus or herpes simplex virus. Overall, the specificity of the Elecsys assay was 99.88% using samples from blood donors and 99.81% when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys HIV combi PT assay has been granted the European Conformity (CE) marking and is now available for use in laboratory-based testing. The study was published in the February 2013 issue of the journal Medical Microbiology and Immunology.

Related Links:
Innsbruck University Hospital
Roche Diagnostics

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.