Language:
Password reminder
No account yet? Register Free
About Us Advertising Info Contact Us Client Login
labmedica.com
Immunology
Features Subscription Partner Sites Journal Info
Veolia WATERRANDOX LABORATORIESAB SCIEX

Automated Chemiluminescence Assay Identifies Antiphospholipid Antibodies

By Labmedica International staff writers
Posted on 02 May 2012


The laboratory diagnosis of antiphospholipid antibody syndrome (APS) requires the demonstration of antiphospholipid antibodies (aPL) by lupus anticoagulant (LAC) measured through coagulation assays.

A new chemiluminescence automated system has been proposed that can improve the reproducibility and reduce interlaboratory variation as the laboratory diagnosis of the APS remains a challenge for each laboratory worker in the field.

Scientists at the Sapienza University (Rome, Italy) analyzed blood samples from 314 consecutive individuals. There were 63 with clinical APS; 73 patients did not show clinical manifestations of APS, but were positive for anticardiolipin antibodies (aCL); 15 patients who were LAC positive, and had shown venous and/or arterial thrombosis; and 163 subjects were healthy blood donors and showed no signs or symptoms of APS.

Serum samples were tested with commercial autoantibody assays and lupus anticoagulant assays. Anticardiolipin antibodies, immunoglobulin G (IgG) and IgM were tested by chemiluminescence assay on the Zenit RA immunoanalyzer (A. Menarini Diagnostics, Florence, Italy). Zenit RA, a random-access immunoanalyzer, uses a two-step immunoassay method based on the principle of chemiluminescence.

The results of the study showed while almost all the sera from APS patients who were positive for IgG aCL and anti-β2- glycoprotein I (GPI) by enzyme linked immunosorbent assay (ELISA), were also positive for IgG aCl by chemiluminescence. Only 30.13% of patients without clinical manifestations of APS confirmed the positive test by chemiluminescence, although were positive for aCL and persistently negative for anti-β2-GPI IgG by ELISA and LAC. Both ELISA tests were products of INOVA Diagnostic Inc. (San Diego, CA, USA).

The highest positivity of aCL by chemiluminescence was detected among patients with rheumatic disorders (50%), followed by patients with neurological disorders (33.3%) or infectious diseases (25%).This group of patients without clinical manifestations of APS, were positive for aCL by ELISA and persistently negative for anti-β2-GPI by ELISA and LAC. The authors concluded that the results suggest that the new technology of automated chemiluminescence assay for measuring aPL may represent a useful tool to identify “true” APS patients. The study was published in the May 2012 issue of the Journal of Immunological Methods.

Related Links:
Sapienza University
A. Menarini Diagnostics
INOVA Diagnostic





Urine Analyzer
Urine Analyzer
ELISA Kit
ELISA Kit
Random Access Analyzer
Random Access Analyzer

More Products

Latest Immunology News

LinkXpress
Click for LinkXpress
Reader Inquiry Service
Enter code to receive information:
Where I can find code?
Featured Whitepaper
SIEMENS DIAGNOSTICS :
Siemens Healthcare Diagnostics Anti-CCP: A Clinical Evaluation Whitepaper

Download Whitepaper
Events
EuroMedLab 2013 - 20th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine
19 May 2013 - 23 May 2013


ELA – European Lab Automation congress
06 Jun 2013 - 07 Jun 2013


European Human Genetics Conference 2013
08 Jun 2013 - 11 Jun 2013


More events
GLOBETECH PUBLISHING
Latest Issue

View Digital Edition
Subscribe / Renew
ALTO MARKETING LIMITED
AACC
DIASOURCE
GREINER-BIO-ONE
KARL HECHT GMBH & CO KG
77 ELEKTRONIKA
BioPorto Diagnostics
  labmedica.com Copyright © 2000-2013 Globetech Media. All rights reserved.
Privacy Policy