We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Primary Screening Test for Diabetes Reevaluated

By LabMedica International staff writers
Posted on 04 Jan 2012
Print article
The blood test for glycosalated hemoglobin, Hb1Ac, has been recently recommended as the primary diagnostic test for diabetes.

The HbA1c blood test is the accepted standard for monitoring long-term glycemic control in patients with diabetes, however until recently, HbA1c was not recommended for diagnosing or screening for diabetes.

In a retrospective study carried out by DynaLIFEDx, Edmonton, AB, Canada) in conjunction with local medical practitioners, evaluated the positive predictive value (PPV) and negative predictive value (NPV) of HbA1c against the oral glucose tolerance test (OGTT) values using a 10% prevalence of diabetes in three locations. DynaLIFEDx is a major Canadian medical laboratory offering a complete range of diagnostic testing services. For a three-year period, 3,163 data pairs were collected including 1,537 males and 1,626 females with a mean age of 55.4 ± 14.7 years. The OGTT criteria for diabetes were found for 568 out of the 3,163 sets.

Blood glucose was measured on the ARCHITECT ci8200 (Abbott Laboratories; Mississauga, ON, Canada) using a hexokinase method and HbA1c was measured by high performance liquid chromatography (HPLC) on a VARIANT II analyzer (Bio-Rad laboratories, Montreal, QC, Canada). The recommended threshold HbA1c value of 6.5% did not give the optimal combination of NPV of 0.93 to 0.92 and PPV of 0.40 to 0.61 compared to a threshold HbA1c value of 7.0% that gave an NPV of 0.91 to 0.92, and PPV of 0.61 to 0.73.

The authors concluded that HbA1c is not satisfactory for use as a diagnostic test for diabetes using the threshold values recommended by the Consensus Committee and the International Expert panel due to low positive predictive values. About 12% of individuals with a normal OGTT test will be diagnosed with diabetes using a threshold HbA1c value of 7.0%. This would put considerable burden on health care resources. However, based on the high negative predictive value, HbA1c may be used as a test to rule-out diabetes. The study was published in the December 2011 issue of the journal Clinical Biochemistry.

Related Links:

DynaLIFEDx
Abbott Laboratories
Bio-Rad


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.