We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Assays Compared For Diagnosis of Mycoplasma Infection

By LabMedica International staff writers
Posted on 23 Nov 2011
Print article
Both molecular and serological assays have been compared for detection of Mycoplasma infection in nasopharyngeal aspirates and serum samples.

Two commercial polymerase chain reaction (PCR) assays including a real-time PCR test, and an oligochromatographic test, and one serology test were compared for the ability to detect Mycoplasma pneumoniae mainly in pediatric patients.

At the Universitat Autònoma de Barcelona (Spain) a total of 145 nasopharyngeal aspirate specimens were collected from June 2008 to December 2009. This included samples from pediatric patients with respiratory infection who presented at the emergency department and healthy children. Serum samples were obtained on admission, and convalescent serum samples were obtained 4–6 weeks later from all patients. Serum samples were tested on reception.

Serum samples were tested against M. pneumoniae using a commercial particle semiquantitative agglutination test kit (Serodia-Myco II test, Fujirebio; Tokyo, Japan, ). This agglutination assay uses gelatin particles sensitized with a crude antigen suspension of M. pneumoniae. The Speed-oligo M. pneumoniae test (Vircell; Granada, Spain) is a PCR-based method coupled to a dipstick device that enables a rapid detection of M. pneumoniae in clinical samples. The real-time PCR was performed with the SmartCycler II instrument (Cepheid; Sunnyvale, CA, USA).

Among the 145 samples, 32 serum pairs were serologically positive for M. pneumoniae. Of these, in 30 nasopharyngeal aspirates, M. pneumoniae was detected using the real-time PCR assay and 25 using Speed-oligo, corresponding to a sensitivity of 93.7% and 78.1%, respectively. Among the 94 samples with negative serology, only one positive result was obtained by real-time PCR assay. In the group of samples from healthy children, no positive results were obtained. M. pneumoniae is a pathogen that is a causative agent of respiratory tract infections

The authors concluded both PCR methods are fast; real-time PCR needs about one hour to complete and Speed-oligo PCR is completed within 55 minutes and detection requires no more than five minutes. However, the laboratory diagnosis of a chosen clinical episode should not rest on the PCR or acute phase serologic assay alone, but must also include antibody assays to confirm whether infection is current or represents persistence from past exposure. The study was published online on October 14, 2011, in the journal Diagnostic Microbiology and Infectious Disease.

Related Links:

Universitat Autònoma de Barcelona
Fujirebio
Cepheid



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.