Stability of Hematological Parameters Tested In Blood Collection Systems

By LabMedica International staff writers
Posted on 26 Oct 2010
Print article
The integrity of a hematological sample is known to depend on time and temperature and the measurement technique has already been found to have an impact on stability.

Two specimen tubes containing an anticoagulant were tested for their affect on the stability of hematological parameters overtime. Full blood count and reticulocyte hematological analyses were conducted on a Beckman Coulter LH750 hematology analyzer (Beckman Coulter, Inc, Brea, CA, USA), at multiple time points up to 72 hours.

The two blood collection systems tested were the Vacutainer from Becton Dickinson, (BD; Franklin Lakes, NJ USA) and the Monovette from Sarstedt Inc., (Newton, NC, USA). In a recent study carried out by Icon Development Solutions (Manchester, UK), twenty healthy volunteers (10 males, 10 females) were recruited. No restrictions were placed on these volunteers. A total of 36.9 mL blood was taken from each volunteer, collected using a cannula into seven 2.7 mL ethylenediaminetetraacetic acid (EDTA) Sarstedt Monovettes and four 4.5 mL EDTA BD Vacutainers. Both types of tube are plastic and contain tri-potassium (K3) EDTA as an anticoagulant. Becton Dickinson tubes contain 7.2 mg K3 EDTA in a 4 mL tube; Sarstedt tubes contain sufficient K3 EDTA to achieve a concentration of 1.2-2 mg EDTA/mL blood, with a maximum dilution effect of 1%.

All parameters matched or exceeded Beckman Coulter stated stability values, with both Sarstedt and BD tubes showing remarkably similar levels of stability for all parameters. The exceptions were that mean platelet volume (MPV) was only stable for 18 hours in BD tubes and 24 hours in Sarstedt tubes, and neutrophils (NE) were stable for 72 hours in BD tubes, but only 48 hours in Sarstedt tubes. However, it was noted that the degradation of the Sarstedt samples appears to be more predictable and follows a much more linear pattern. Accurate full blood count results can be obtained on samples up to 48 hours, provided that the samples are stored in a refrigerator. The tube type was found to have minimal impact on the stability of hematological samples. The study was published in October 2010 in the British Journal of Biomedical Science.

Related Links:
Beckman Coulter
Becton Dickinson
Sarstedt
Icon Development Solutions

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: The cobas Malaria test is the first FDA-approved molecular test to screen U.S. blood donors for malaria (Photo courtesy of Roche)

First FDA-Approved Molecular Test to Screen Blood Donors for Malaria Could Improve Patient Safety

Malaria, a serious illness that often leads to death, is spread by a specific mosquito species that infect humans with a parasite. Other transmission modes include blood transfusions, organ transplants,... Read more

Pathology

view channel
Image: The medical office procedure detects the key biomarker in Parkinson’s and related neurodegenerative diseases (Photo courtesy of BIDMC)

Simple Skin Biopsy Test Detects Parkinson’s and Related Neurodegenerative Diseases

Parkinson's disease and a group of related neurodegenerative disorders known as synucleinopathies impact millions globally. These conditions, including Parkinson’s disease (PD), dementia with Lewy bodies... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.